16.5      Outbound Conveyor System

The following design standards shall be met:

A.     Ticket Counter/Curbside - Standard ticket counter or curbside load conveyor belt speed shall be 90 Feet per Minute (FPM).

B.     Meet or exceed structural floor slab requirements per machine, as stated by EDS supplier.

C.      Comply with TSA and FAA noise requirements for staffed areas.

D.     Provide a tug aisle clear height of 8’-0” (minimum) from finished floor to lowest hanger or drive component.

E.      Make-up unit control stations shall be located within a 16” to 22” arm reach from the perimeter of the unit.